Doosan D80S-5 — Doosan D80S-5 User Manual

Operation Section Changing LP Tanks Only trained, authorized personnel should fill or exchange LP tanks. Personnel engaged in filling of LP containers should wear protective clothing such as face shield, long sleeves and gauntlet gloves. Do not refuel or store LP powered lift trucks near any underground entrance, elevator shafts or any other place where LP could collect in a pocket causing a potentially dangerous condition. Examine all LP containers before filling and again before reuse, for damage to various valves, liquid gauge, fittings and hand valve wheels. All defective or damaged LP containers must be removed from service. Explosive fumes may be present during refueling.

Do not smoke in refueling areas. Lift truck should be refueled only at designated safe locations. Safe outdoor locations are preferable to indoor locations. Stop the engine and get off the lift truck during refueling. The careless handling of LP containers can result in a serious accident. Use extreme care when transporting containers to prevent damage to them. 4. Grasp the tank support bar (1). Pull and release the latch switch (2). 5. Grasp the tank support bar (1) and rotate cradle slowly to the rear of a tank. 6. Pull the release knob (1) and then push down the tank. 1.

Park the lift truck on level ground, with the parking brake applied, the transmission in NEUTRAL, the forks lowered and the engine running at low idle. 7. Lock the tank cradle by knob (1). Loosen the retaining clamps (2) and remove the tank. 8. Check the mounting to be sure the locating pin (dowel) is not missing or broken. 2. Close the fuel inlet valve at the LP - Gas tank. Run the engine until it stops, then turn off the ignition switch and the electrical disconnect switch (if equipped). 3. Disconnect the fuel supply line. NOTICE If the location pin (dowel) is missing or broken, be sure the pin is replaced. 61 WARNING