Doosan D80S-5 — Doosan D80S-5 User Manual

Operation Section Table 2. MI-07 Diagnostic Fault Codes (Flash Codes) cont’d. (*) Fault actions shown are default values specified by the OEM. 93 DFC PROBABLE FAULT FAULT ACTION * CORRECTIVE ACTION FIRST CHECK 242 TPS2AdaptLoMin Learned closed throttle end of TPS2 sensor range lower than expected None Check the throttle connector and pins for corrosion. To check the TPS disconnect the throttle connector and measure the resistance from:

TPS Pin 2 (GND) to Pin 5 (TPS2 SIGNAL) (1.3K Ω ± 30%) TPS PIN 3 (PWR) to PIN 5 (TPS2 SIGNAL) (0.6K Ω ± 30%) 251 (25) TPS1AdaptHiMax Learned WOT end of TPS1 sensor range higher than expected None N/A 252 TPS2AdaptHiMax Learned WOT end of TPS2 sensor range higher than expected None N/A 271 TPS1AdaptHiMin Learned WOT end of TPS1 sensor range lower than expected None N/A 272 TPS2AdaptHiMin Learned WOT end of TPS2 sensor range lower than expected None N/A 281 TPS1AdaptLoMax Learned closed throttle end of TPS1 sensor range higher than expected None N/A 282 TPS2AdaptLoMax Learned closed throttle end of TPS2 sensor range higher than expected None N/A 291 TPS Sensors Conflict _ _ TPS sensors differ by more than expected amount NOTE:

The TPS is not a serviceable item and can only be repaired by replacing the DV-EV throttle assembly. (1) TurnOnMil (2) Engine Shutdown Perform checks for DFCs 241 & 242