S0802195K Page 43 Electrical System Fault Code Light J1587 PID(P) SID(S) FMI J1939 SPN FMI Reason Effect 432 Red S230 13 558 13 Voltage detected at idle validation on-idle circuit when voltage at throttle position circuit indicates the pedal is not at idle OR voltage detected at idle validation off-idle circuit when voltage at throttle position circuit indicates the pedal is at i Engine will only idle. 433 Yellow P102 2 102 2 Voltage signal at intake manifold pressure circuit indicates high intake manifold pressure but other engine characteristics indicate intake manifold pressure must be low. Derate to no air setting.
434 Yellow P251 2 627 2 Supply voltage to the ECM fell below 6.2 VDC for a fraction of a second OR the ECM was not allowed to power down correctly (retain battery voltage for 30 seconds after key off.) Possible no noticeable performance effects OR possibility of engine dying OR hard starting. Fault information, Trip information, and maintenance monitor data may be inaccurate. 435 Yellow P100 2 100 2 An error in the oil pressure sensor signal was detected by the ECM. None on performance. No engine protection for oil pressure. 441 Yellow P168 1 168 18 Battery voltage below normal operating level. Possible no noticeable performance effects OR possibility of rough idle.
442 Yellow P168 0 168 16 Battery voltage above normal operating level. None on performance. 443 Yellow P221 4 1043 4 Low voltage detected on the ECM voltage supply line to throttle(s) (VTP supply). Engine will only idle. 489 Yellow P191 1 191 18 Auxiliary speed frequency on input pin indicated that the frequency is below a calibration dependent threshold. Engine will only idle. 527 Yellow P040 S1543 702 3 Less than 17.0 VDC detected at the dual output A signal pin of the 31- pin OEM connector. No action taken by the ECM. 528 Yellow P093 2 93 2 Less than 17.0 VDC detected at the dual output B signal pin of the 31- pin OEM connector.
No action taken by the ECM 529 Yellow S051 3 703 3 Less than 17.0 VDC detected at the dual output B signal pin at the ECM. No action taken by the ECM. 551 Yellow S230 4 558 4 No voltage detected simultaneously on both the idle validation off-idle and on-idle circuits. Engine will only idle. 581 Yellow P105 3 1381 3 High voltage detected at the fuel inlet restriction sensor signal pin. Fuel inlet restriction monitor deactivated. 582 Yellow P105 4 1381 4 Low voltage detected at the fuel inlet restriction sensor signal pin. Fuel inlet restriction monitor deactivated. 583 Yellow P105 1 1381 18 Restriction has been detected at the fuel pump inlet. Fuel inlet restriction monitor warning is set.