Komatsu — HANDLING BATTERY DISCONNECTOR SWITCH

. ATTACHMENTS, OPTIONS HANDLING BATTERY DISCONNECTOR SWITCH HANDLING BATTERY DISCONNECTOR SWITCH CAUTION maintenance of the electrical system. radio station selection are lost. 6 - 41 When the engine is running, do not operate the battery disconnector switch to shut off the elec trical circuit. When the circuit erated, and this may damage the electric circuit or the controlle Keep this switch at the ON (con nected) position except when putting the machine into long-term storage or when carrying out Before turning the battery disco nnector switch to the OFF (disconnected) position, always tur n the starting switch OFF, and the engine stops.

If the battery disconnector switch is turned OFF (disconnected) when the e engine is running, there is danger of failure or abnormality occ urring in the electrical system. When the switch is turned to the OFF (disconnected) position , all electrical systems are shut off , and the data for the clock and The battery isolator prevents c onsumption of the battery power caused by short circuit s or electrical leakage from the equipment during long-term When repairing any electrical c ircuit or carrying out welding operations, cut the battery disconnector switch (at the position marked by the arrow i n the diagram below) to prevent damage to the electrical