mercedes-benz — Mercedes-Benz Unimog 421-411 Service Workshop Manual Volume 1

43.3 Control Equipment Shutoff Valve 5 Part No. Westinghouse Designation 452 002 007 0 4520021070 0004291031 0004291431 Technical Data 4. Operating pressure max. 8 bar Version Handle deflects 90 ° in both directions Thread connection M 22 x 1.5 1 Housing UZ 43-0065 2 Camshaft 3 Lever 4 Valve 5 Evacuation Installation Instructions Disassembly, Inspection and Assembly The shutoff valve is located in front of the rear coupling head of tractor unit. Observe flow rate direction of arrow. Install in such a manner as to ensure access to and operate of handle. Shutoff valve removed 1 Clamp shutoff valve in vice input connection on top. 2 Unscrew guide nut for valve stem and remove valve assembly.

3 Change position of housing in vice bottom closure up. 4 Unscrew closing plug pay attention to sealing ring, remove spring. 5 Change position of housing in vice handle up. 6 Force cross pin out of handle and knock cam shaft out in downward direction including sealing washer. 7 Clean all parts, replace damaged parts. 8 Assembly takes place in the reverse sequence. Slightly grease all parts first.