Checking Cooling system 20.9 616 Checking The cooling system operates at overpressure con trolled by the valve in the inlet lock of the expansion tank. When the coolant is heated, the overpressure valve maintains the system under pressure up to 0.5 kp/cm2 while the vacuum valve balances any harmful vacuum during cooling. The pressurized cooling system must therefore be checked for leaks when cold. 1 Unscrew closing cover from expansion tank. 2 For checking, top up coolant to maximum level so that too much air does not require to be compressed. 3 Fit special tool No. 1. 4 Pump up to approx. 0.5 km/cm2 with test pump and check whether pressure remains stationary.
If there is a pressure drop, repair defect points. Even if pressure remains stationary, check hose connec tions for needle hole leaks sweating. The following characteristics may occur: 5 If the pointer on the tester fluctuates, this is usually an indication that the cylinder head gasket is leaking. 6 Loss of coolant via the overflow pipe is indicated bya sudden rise and then a drop in the test pressure. This can be caused by furring in the water jacket, caused by local hot spots which result in steam bubbles being formed and water thus being ejected. To rectify, have engine or entire cooling system defurred. 7 Test closing cover with special tool No 1 In