. MAINTENANCE MAINTENANCE PROCEDURE CHECK AND MAINTENANCE AIR CONDITIONER Check Level of Refrigerant (gas) WARNING Inspection and Maintenance Items 4 - 34 If the refrigera nt used in the air conditione r gets into yo ur eye s or on y our hands, it may ca use loss of sight or fro stbite. Do not touch the refri gerant. Never loo sen any p art of t he refr igerant circuit. leaking. Do not bring a ny flame close to any point where the ref rigeran t ga s is leaking. If there is a lack of refr igerant (Freon 134a), the cooling at high speed, there should be no cooling performance When opera will be poor. ting the cooler bubbles in th condenser u e sight glass (1 nit receiver.
) (inspection window) mounted on the (A) No bubb les in refrigerant flow: Sui table (B) Some bu bbles in flow (b ubbles pa ss continuously): Lack of refri gerant s, transparent: No refrigerant (C) Colorles s, transparent: N o refrige REMARK When there are bubbles, the refrigera nt gas level i s low, so contact your Komat su distributors t o have r efrigerant added. If the air conditioner i s run with the r efrigerant will damage to t he compressor. Inspection During Off Seaso n Even during the off-season, operate t he air conditioner f or 3 to 5 minutes once a m onth to maintain th e oil film at al parts of the compressor.
Check, maintenance items Content of check, maintenance Guideline for maintenance interval Refrigerant (gas) Charge amount Twice a year (spring, autumn) Air conditioner condenser Clogged fins Every 500 hours Compressor Operating condition Every 4000 hours V-belt Damage, tension Every 250 hours Blower motor, fan Operating condition (does it make abnormal noise?) When required Control mechanism Operating condition (does it function normally?) When required Piping mounts Mounting condition, looseness at tightening or connecting portions, leakage of gas, damage When required