EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL use of a higher TBN oil. For detailed information refer to publication Engine Requirements – Lubricating Oil, Fuel and Filters (7SE270), available from authorized Detroit Diesel distributors. USED ENGINE OIL To avoid injury to skin from contact with the contaminants in used engine oil, wear protective gloves and apron. Disposing of Waste Oil The maximum interval at which the engine may operate before the oil and filters must be changed is listed in Table 18. Dispose of used lubricating oil and filters in an environmentally responsible manner, according to federal (EPA) and/or state recommendations.
The disposal of waste oil may be best addressed by the engine oil supplier, who may accept responsibility for proper disposal of this material as part of the business of providing lubricant. Oil analysis may be used to determine whether this interval should be shortened, but it should not be used to lengthen the interval. The use of fuels with sulfur content above 0.05 mass percent will require a shortening of drain intervals and/or the Table 18 Maximum Oil Drain and Filter Change Interval (Fuel Sulfur 15 ppm Weight Percent or Less) All information subject to change without notice.
93 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION Engine Application Drain Interval Highway Truck & Motor Coach 30,000 Miles (48,280 km) Fire Truck or Crash/Rescue Vehicle 6,000 Miles (9,600 km), 300 Hours or 1 Year, whichever comes first