MAN — Man EPA07 Series 60 Engine Operator's Manual

EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL handle on the shutoff valve to the closed position (perpendicular to the valve). 8. Turn the handle on the shutoff valve to the Open position (in line with the valve). NOTICE: Have replacement filters filled with fuel and ready to install immediately. This prevents possible siphoning and fuel system aeration. ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 4. Using a suitable band type filter wrench, remove the primary and secondary fuel filters. Dispose of the filters in an environmentally responsible manner, according to federal (EPA) and/or state recommendations.

9. Start the engine and check for leaks. Shut down the engine. Correct any leaks with the engine off. 5. If not previously filled, fill new replacement filters with clean diesel fuel and coat the gaskets lightly with the fuel. NOTICE: Never use the starting motor and fuel pump to prime the fuel filters. Prolonged used of both to prime the fuel system can result in damage to the starter, fuel pump and injector. 6. Thread the new filters onto the adaptor inserts until the gaskets make full contact with the adaptor head and no side movement is evident. If the engine fails to start after filter replacement, the fuel system will require priming with tool J 5956 (or equivalent).

Authorized Detroit Diesel distributors are properly equipped to perform this service. NOTICE: Overtightening the filter may crack or distort the adaptors. 7. Tighten filters an additional one-half turn by hand, or as indicated on the filter. All information subject to change without notice. 99 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION