MAN — Man EPA07 Series 60 Engine Operator's Manual

EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL Table 19 Coolant Terms Approved Coolants NOTICE: Required specifications for water, ethylene glycol, propylene glycol, inhibitor packages and inhibitor concentration are included in this section. To avoid engine damage from inadequate or over concentrated coolant, the required specifications must be adhered to before the coolant is replaced. All information subject to change without notice.

107 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION Term Definition Antifreeze Ethylene glycol (EG) or propylene glycol (PG) containing a corrosion inhibitor package and which meets an appropriate heavy-duty specification (i.e., TMC RP-329 “Type A” for ethylene glycol or TMC RP-330 “Type A” for propylene glycol). Coolant The fluid mixture circulating in the engine cooling system, typically a mixture of 50% water and 50% antifreeze. Drop–Out Precipitated sludge or deposit formation on cooling system components. Fully Formulated Antifreeze Contains all the necessary inhibitors to protect a diesel engine, and does not, therefore, require a pre-charge of SCA before its first use.

Initial–Fill Coolant The coolant that is used in a new or rebuilt engine, or any time the cooling system is emptied and then refilled with coolant. OAT Organic Acid Technology. An inhibitor system based on organic acid inhibitors, instead of traditional North American inhibitor formulations. SCA Supplemental Coolant Additive. SCAs are used in a preventive maintenance program to prevent corrosion, cavitation, and the formation of deposits.