EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL must meet TMC RP-330 “Type A” requirements. transfer, reduced freeze protection (IEG only), and possible silicate dropout. An antifreeze concentration below 33% (33% antifreeze, 67% water) offers too little freeze and/or corrosion protection and is not recommended . Fully formulated antifreeze does not require a dosage of SCA prior to initial use. Mixing EG or PG Antifreeze and Water If a concentrated ethylene glycol (EG) or propylene glycol (PG) antifreeze is purchased, mix the antifreeze with water meeting the required quality standards listed in Table 23 and fill the cooling system.
Always verify that the freeze point and nitrite concentration of the antifreeze/water mixture are correct by using a POWER Trac ® 3–Way Coolant Test Strip. If chemical analysis is used, elements in the coolant must fall within the limits listed in Table 21. If a pre-diluted, fully formulated coolant is purchased, fill the cooling system. For best overall performance, a coolant consisting of 50% concentration of antifreeze (50% antifreeze, 50% water) is recommended .
Recycled Antifreeze — Antifreeze or coolant recycled by reverse osmosis, distillation, and ion exchange, properly re-inhibited to meet TMC RP-329 Type A or TMC RP-330 Type A requirements, has been demonstrated to provide service equivalent to virgin antifreeze. An antifreeze concentration over 67% (67% antifreeze, 33% water) is not recommended due to poor heat Table 21 Fully Formulated Glycol Coolant Limits with TMC RP-329, TMC RP-330 Chemistry Type A (50/50 Coolant/Water Mixture) All information subject to change without notice.
109 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION Fully Formulated Glycol Coolant Concentration Limits Boron 125 – 500 PPM Nitrite 900 – 3200 PPM Nitrate 200 – 1000 PPM Silicon 50 – 250 PPM Phosphorous 0 PPM pH 8.0 – 11.0