MAN — Man EPA07 Series 60 Engine Operator's Manual

EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL soft water and required inhibitors. If the engine is to be exposed to freezing temperatures, install genuine Detroit Diesel Power Cool antifreeze or an equivalent ethylene glycol-base or propylene glycol-base antifreeze solution which provides required freeze, boil over, and inhibitor protection. Refer to section How to Select Coolant. FOR STARTING THE ENGINE section of this guide. ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 9. Install and connect the battery. Make sure the average specific gravity of the battery is 1.260 or higher.

Charge the battery, if necessary. 14. After all preparations are completed, start the engine. NOTE: The small amount of rust preventive which remains in the fuel system will cause smoky exhaust for a few minutes. 10. Service the air cleaner, if required. 11. Transmission: Follow the manufacturer's recommendations covering the return of the transmission to service. 12. Power Take-Off: If equipped, follow the manufacturer's recommendations covering the return of the power take-off to service. NOTE: Before subjecting the engine to a load or high speed, allow it to reach normal operating temperature. 13. Turbocharger:

Remove the covers from the turbocharger air inlet and turbine outlet connections. Reconnect piping as required. Prelube the turbocharger center bearing housing. Refer to Lubrication System Checks in the OPERATING INSTRUCTIONS 15. Check for trouble codes. [a] If there are no codes, perform a parked regeneration. [b] If there are codes, repair what is necessary then perform a parked regeneration. All information subject to change without notice. 133 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION