MAN — Man EPA07 Series 60 Engine Operator's Manual

DDEC VI SYSTEM Engine speed is rpm and the SEO switch is put in the ON position. seconds. The pause between codes is 3.5 seconds. The same 3.5 second pause occurs as the switch is made from RSL (Stop Engine) to AWL (Check Engine). See Figure 17. Idle Governor is active and the SEO switch is put in the ON position. When code flashing is initiated, the active codes will be flashed on the RSL (Stop Engine). Then the inactive codes will be flashed on the AWL (Check Engine). When all the inactive codes have been flashed, the process of flashing all the active codes followed by all the inactive codes will repeat until the conditions for code flashing are no longer satisfied.

Vehicle speed is Brake is activated and the SEO switch is put in the ON position. The flashing code feature is deactivated once the SEO switch is returned to the OFF position or the listed conditions are no longer satisfied. Only one light will be flashing codes at any time. All codes will be flashed twice. The inter-digit pause is 1.5 If there are no active or inactive faults the number 3 is flashed once followed by an inter-code gap of 3 seconds. Figure 17 RSL (Stop Engine) Flashing Code Example 42 All information subject to change without notice. DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION