MAN — Man EPA07 Series 60 Engine Operator's Manual

EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL To initiate a parked regeneration, perform the following: The regeneration is completed when the engine returns to low idle and the DPF Lamp remains off. The High Exhaust System Temperature (HEST) Lamp will remain on but the vehicle can be driven. 1. Keep engine at slow idle (cannot be in PTO mode). 2. Transmission is in neutral with parking brake ON. If the Parked Regeneration exits and the DPF Lamp remains on, repeat the procedure. If the second try also fails, contact the Detroit Diesel Customer Support Center at (313) 592-5800. 3. Cycle the parking brake from OFF to ON. NOTE:

Air tank pressure must be high enough for the parking brake switch to hold in the OFF position. NOTE: A Parked Regeneration will stop if the key is turned to the OFF position, the vehicle is put into gear, or the parking brake is released. 4. Press and release clutch pedal (if equipped with clutch pedal). 5. Cycle transmission to DRIVE and back to NEUTRAL (if not equipped with clutch pedal). Hazardous Applications The MCM should be configured to not allow automatically triggered over-the-road regenerations (DPF Manual Regen Only Enable = Enabled). 6. Hold DPF Switch in the ON position for five seconds and then release (engine speed will increase and DPF Lamp will go out). NOTE:

This is for hazardous applications only. There are two CPC options: DPF Stationary Regen Only = 0-Disabled DPF Stationary Regen Only = 1-Enabled The regeneration will take up to 40 minutes. All information subject to change without notice. 57 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION