EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL Preventive Maintenance Intervals Add the proper grade of oil to maintain the satisfactory range on the dipstick. See Figure 20. This section describes the items listed in the maintenance interval tables. The “Daily” instructions apply to routine or daily starting of the engine. They do not apply to a new engine or one that has been operated for a considerable period of time. For new or stored engines, refer to the Series 60 Service Manual (6SE483). Follow instructions in Section 13.1 under Preparations for Starting the Engine the First Time . Figure 20 Check Oil Level Daily NOTICE:
Preventive maintenance other than the “Daily” checks should be performed by authorized Detroit Diesel service outlets. These outlets have the trained personnel and special tools to properly perform all services. When adding lubricating oil, do not overfill. Oil may be blown out through the crankcase breather if the crankcase is overfilled. Item 1 Lubricating Oil All diesel engines are designed to use some oil, so the periodic addition of oil is normal. See Figure 21 to determine the degree of oil usage. Check the oil level daily with the engine stopped.
If the engine has just been stopped and is warm, wait approximately 20 minutes to allow the oil to drain back into the oil pan before checking. The dipstick has an operating range identified by a crosshatch. If the oil meniscus is within this crosshatch range then the oil range is adequate for engine operation. All information subject to change without notice. 73 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION