MAN — Man EPA07 Series 60 Engine Operator's Manual

EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL Item 2 – Fuel and Fuel Tank Keep the fuel tank filled to reduce condensation. See Figure 22. PERSONAL INJURY To avoid injury from improper use of chemicals, follow the chemical manufacturer’s usage, handling, and disposal instructions. Observe all manufacturer’s cautions. NOTICE: Figure 22 Filled Fuel Tank Never use galvanized steel fuel tanks, fittings, pipes or supply lines. The fuel reacts chemically with the zinc coating to form powdery flakes that can quickly clog the fuel filters and damage the fuel pump and injectors. Before adding fuel, refer to How to Select Diesel Fuel in the HOW-TO SECTION of this guide.

Refill the tank at the end of each day's operation to prevent condensation from contaminating the fuel. Condensation formed in a partially filled tank promotes the growth of microorganisms that can clog fuel filters and restrict fuel flow. Open the drain at the bottom of the fuel tank every 30,000 miles (48,280 kilometers) to drain off any water and/or sediment. To prevent microbe growth, add a biocide to the fuel tank or primary fuel supply. Water accumulation can be controlled by using additives containing methyl carbitol or butyl cellusolve. Follow manufacturer's usage, handling and safety precautions.

Every 120,000 miles (192,000 kilometers) or 12 months tighten all fuel tank mountings and brackets. At the same time, check the seal in the fuel tank cap, the breather hole in the cap and the condition of the flexible fuel lines. Repair or replace the parts, as necessary. All information subject to change without notice. 75 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION