Komatsu — CHECK BEFORE STARTING ENGINE, ADJUST

. OPERATION OPERATION CHECK ELECTRIC WIRING WARNING CHECK BRAKE PEDAL TRAVEL WARNING 3 - 97 If fu ses are frequently blown or if there is a short circuit in the electri cal wiring, locate t he c ause and repair or c ontac t your Komatsu distributor. Accumulation of flammable m aterial (dead leaves, twigs, gr ass, etc.) a round the battery may cause fire , so alway s chec k and remove such material. Kee p the top surface of the b attery clean and check the brea ther hole i n the battery cap. I f it is clogged with dirt o r dust, wash the battery cap to clear the b Chec k for damage and wron g capacity of the fuse and an y sign of disconnection or sho rt circuit i n the electric w iring.

Chec k also for loose termina ls and tighten any loose pa Chec k the wiring of the "batt ery", "starting motor" and "a lternator " carefully in particul Alway s check if there is any accumulation of flammable material around the battery, and r emove such flammable material. Pleas e contact your Komats u distributor for investigatio n and cor rection of the cause. If t he b rake pedal stroke is not 6 0 to 80 mm (2.4 to 3.1 in) (below 60 mm or over 80 mm), the b rake and s teering force i s too s trong or insufficient. If the stroke is 81 mm (3.1 in) or longer, adjust i t. 1. D epress the brake pedal all the way until it stops. 2.

C heck that the distance of travel (A) at the center of the peda is 60 to 80 mm (2.4 to 3. 1 in). 3. W hen this value exceed s 81 mm (3.1 in), or the bra ke fails t w ork, please contact you r Komatsu distributor for a djustment