Section 03 ELECTRONIC MANAGEMENT SYSTEMS Subsection 04 (MONITORING SYSTEM AND FAULT CODES) Start engine. Check if fault code disappeared. The electronic system will react differently de- pending on the fault type. In severe failure, the engine may not be allowed to be started. In other cases, the engine will operate in limp home mode (reduced speed). The following conditions will trigger a limp home mode. Limp Home Mode When a major component of the EMS or the iBR is not operating properly the limp home mode will be set. Engine speed will be limited and therefore vehicle speed. This mode allows the rider to go back home which would not be otherwise possi- ble without this advanced system.
LIMP HOME MODE will be displayed in the information center. The performance-reduced modes or safety-re- lated modes allow the rider to go back home which would not be otherwise possible without this advanced system. The following conditions will stop the suspension. Indicator Lights and Message Display Information Indicator lights (pilot lamps), located in the speedometer and tachometer indicator, inform the rider of a selected function, a normal condi- tion, a system anomaly, or a serious malfunction. Major Fault and Vehicle Reaction The following EMS conditions will trigger a limp home mode.
188 smr2009-029 iBR PROBLEM SYSTEM BEHAVIOR Any active fault code related to the iBR that prevents its proper operation iBR gate will be moved and locked in forward position (if possible) Engine will be set in limp home mode (reduced speed) iS PROBLEM SYSTEM BEHAVIOR Any active fault code related to the iS that prevents its proper operation Suspension operation will be disabled. It will remain at the position it was when the fault code was set. ENGINE PROBLEM MAX ALLOWED RPM High engine temperature (from 110°C (230°F)) 3000 High exhaust temperature (from 110°C (230°F)) 3000 Low oil pressure (below 180 - 220 kPa (26 - 32 PSI)) 2500