8 Encoder diagnostics | Diagnosis for encoders with DRIVE-CLiQ interface 8.7 Diagnosis for encoders with DRIVE-CLiQ interface 8.7.1 Online diagnostics screen 1 2 3 4 5 8 6 7 Figure 53: Online diagnostics screen 1 Status bars 2 Reset the minimum values 3 Referencing status 4 Position display 5 Mounting clearance (optional) 6 Position value 7 Revolutions 8 Status The Online diagnostics screen uses status bars to display the current diagnostic values of an encoder with DRIVE-CLiQ interface. For the supported interfaces see "Information on the product", Page 10. Status bars for function reserves The status bars (1) of the Online diagnostics screen show the status of the function reserves.
Up to four function reserves are supported, depending on the encoder. The following function reserves are displayed for absolute encoders with serial interfaces: Abs.Tr. : Absolute track Inc.Tr. : Incremental or scanning track Pos.Val. : Position value calculation The following function reserves are displayed for incremental encoders with purely serial interfaces: Inc.Tr. : Incremental or scanning track Ri.Width : Reference pulse width or sum Ri.Pos. : Reference pulse position HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024 117