Encoder diagnostics | Diagnosis for encoders with DRIVE-CLiQ interface 8 Changing the unit of the measured position values You can choose between displaying measured position values in μ m, ° (degrees), or steps. If you select μ m / ° , the product will display the measured values in μ m or in ° (degrees), depending on the encoder. Tap More The More menu is opened Tap Units The Display settings screen is opened Tap the desired unit The desired unit takes effect Tap Back The changed settings take effect The Display settings screen is closed 8.7.6 Encoder status screen Figure 60:
Encoder status (DRIVE-CLiQ) screen The Encoder status screen can be called from the following screens, using the Status button: Online diagnostics screen Temperature screen Position screen The Encoder status screen displays messages and warnings informing the user about errors that occurred on the encoder and about the transmission status of the encoder. If you use the DRIVE-CLiQ interface to connect encoders to the product, the product evaluates the position data and status information each time position data is transmitted. 124 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024