Specifications | Product data 15 15.1 Product data Electrical data of the device Power supply DC 24 V ± 10 %, max. 15 W Measurement of supply voltage and supply current Voltage: ± 1 % min. ± 10 mV Current: ± 2 % min. ± 1 mA Electrical data of the wall adapter power supply The wall adapter power supply must comply with the following specifications: Rated voltage DC 24 V ± 10 % Leakage current Electrical separation through the use of SELV or PELV circuit Encoder input X1 15-pin D-sub connection, female Current limit: 750 mA @ 5 V ( P ) Information about the cable lengths: When using HEIDENHAIN cables: Ensure that the supply voltage range of the encoder is maintained.
EnDat 2.1 EnDat 2.2 EnDat 3 Cable length: Functional limit frequency or data rate Compliance with test limits signals) Input frequency of incremental signals 1) : 1 V PP Cable length: Functional limit Compliance with test limits Input frequency of incremental signals 2) : TTL Cable length: Functional limit edge separation Compliance with test limits Input frequency of incremental signals 2) : Edge separation > 20 ns 11 µA PP Cable length: Functional limit Compliance with test limits Input frequency of incremental signals 2) : 158 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024