5 Installation | Connecting encoders Fanuc, Mitsubishi, Yaskawa, Panasonic interfaces Pin Function 1, 3, 7, 9, 11, 14 Incremental signals (if available, only for adjusting; do not use in normal operation) 2, 4, 10, 12 Power supply 5, 8, 13, 15 Serial data transfer 6 / For Fanuc signal assignment, see "G", Page 36. For Mitsubishi signal assignment, see "H", Page 36. For Yaskawa and Panasonic signal assignment, see "I", Page 36. Fanuc and Mitsubishi: Do not use pins 5 and 13 for one-pair transmission. DRIVE-CLiQ interface Pin Function A, B Power supply 1, 2, 3, 6 Serial data transfer For the signal assignment of DRIVE-CLiQ, see "P", Page 37.
1 V PP interface (1 V PP /Z1, 1 V PP with limit positions, 1 V PP with clock/data) Pin Function 1, 3, 7, 9, 11, 14 Incremental signals 2, 4, 10, 12 Power supply 5, 6, 8, 13, 15 Other device-dependent signals (switched internally) For 1 V PP signal assignment with limit positions, see "J", Page 36. For 1 V PP /Z1 signal assignment , see "K", Page 36. For 1 V PP signal assignment with clock/data, see "L", Page 36. 11 μA PP interface Pin Function 1, 3, 7, 9, 11, 14 Incremental signals 2, 4 Power supply 5, 8, 10, 12, 13, 15 / 6 Internal shield For 11 μA PP signal assignment, see "M", Page 36. HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024 35