Encoder diagnostics | Diagnosis for encoders with serial interface 8 Shifting the datum A customer-specific datum shift can be performed for encoders with an EnDat interface, for example. The datum shift enables you to adapt the encoder to the machine and the motor for each individual axis (e.g., for measuring the rotor position on synchronous motors). DANGER Danger of uncontrolled movement of the motor / machine axis caused by incorrectly set datum! An incorrectly set datum (field angle on synchronous motors) may cause undesired reactions of a motor that may result in uncontrollability of the motor. Uncontrolled movements of machine axes may result in serious personal injury or death.
Do not change the datum settings Adjust the datum after exchanging the encoder For battery-buffered devices, observe the information provided by the machine manufacturer If you have any questions, contact the machine manufacturer or HEIDENHAIN Set the datum only while the encoder is at a standstill Before repeating a datum shift (e.g., for correction), you first need to cancel the current datum shift For encoder versions with incremental signals (ordering designations EnDat01 and EnDat02), select the Datum shift compliant with incremental signals checkbox in the Datum shift menu Observe the machine manufacturer's and the encoder manufacturer's documentation WARNING Danger of vertical or hanging machine axes!
If vertical or hanging machine axes are not secured, this may cause uncontrolled movement of these axes and may result in serious personal injury or death. Secure vertical or hanging axes against sagging Changing the datum shift in the encoder can, for example, require a new acceptance test for functional-safety applications. For linear encoders, set the datum shift so that no values the position value. EnDat 2.2 does not support negative position values. Instead of a negative sign, EnDat 2.2 outputs the position value: "2 Number of clock pulses for transfer of position value" Certain applications may require commissioning the system after a datum shift has been performed.
72 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024