heidenhain PWT 100, PWT 101 — Assignment of zero position to signal period

Encoder diagnostics | Diagnosis for encoders with serial interface 8 Assignment of zero position to signal period The product checks the settings of the connected encoder and sets the Datum shift compliant with incremental signals checkbox by default to the recommended setting. You can change the recommended setting (where applicable). The assignment of the zero position to the signal period (incremental signal) is taken into account. The product calculates the new datum such that in relation to the incremental signals its position corresponds to the EnDat specification, i.e. is as close as possible to the desired position.

For EnDat01 and EnDat02 encoders, the assignment to the signal period must be taken into account. The assignment of the zero position to the signal period (incremental signal) is not taken into account. Datum shifts that do not take the assignment of the zero position to the signal period (incremental signal) into account are used for purely serial encoders. Purely serial encoders are encoders that do not output incremental signals. Interface designations for purely serial encoders are designations such as EnDat22 and EnDat21. 74 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024