heidenhain PWT 100, PWT 101 — 8.4.8 Encoder status screen

Encoder diagnostics | Diagnosis for encoders with serial interface 8 Classification of status messages The messages displayed by the product for the serial interface are classified as follows: Message Description Transmission errors Transmission errors indicate communication errors that may be caused by EMC influences, for example. Examples of transmission errors that may be displayed: Timeout CRC error Certain interfaces, such as EnDat, provide measures for protecting the transmission between the encoder and the subsequent electronics from transmission errors. Transmission can be protected by means of a CRC (cyclic redundancy check), for example.

Encoder errors Encoder errors indicate a malfunction of the encoder. Encoders with EnDat 2.2 interface may display the following encoder errors, for example: Bit 0 – Light source failure Bit 1 – Signal amplitude faulty Bit 2 – Position faulty Bit 3 – Overvoltage Bit 4 – Undervoltage supply Encoders with Fanuc, Mitsubishi, Yaskawa or Panasonic interface display the Group alarm message without any detailed information If encoder errors are displayed, incorrect position values must be assumed. Operating condition error sources are displayed where appropriate. Operating condition error sources are extended encoder errors.

Encoder warnings Encoder warnings indicate that certain tolerance limits of the encoder have been reached or exceeded. Encoders with EnDat 2.2 interface may display the following encoder warnings, for example: Bit 1 – Temperature exceeded Encoders with Fanuc, Mitsubishi, Yaskawa or Panasonic interface display the Group warning message without any detailed information The encoder warnings displayed do not state whether the measured position values are correct or incorrect. 76 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024