Encoder diagnostics | Diagnosis for encoders with TTL/HTL/HTLs/ interface 8 8.6.1 Level display screen for TTL/HTL/HTLs 1 2 3 3 4 5 Figure 37: Level display screen 1 Warning for signal evaluation 2 Reset drag indicator or warning for signal evaluation 3 Count value 4 Reference mark status 5 Status The Level display screen shows the levels of the individual signals of encoders with TTL and HTL interface. The graphic shows the possible number of signals that can be tested. The inner area shows the evaluation of the low level, and the outer area the evaluation of the high level. If signals are missing, the respective area of the graphic remains white.
The product uses the following colors to display the signals: Color Status Description Green Adequate The signal is within the specified range Red Not sufficient The signal is outside the specified range White No value The signal has not yet been evaluated or the signal is not available Depending on the respective signal, the level of each individual signal and the difference in levels are checked. The following monitoring limits apply (shown as approximate values without indication of tolerance): TTL Single level: Difference in levels: > 0.85 V HTL Single level: 4.4 V Difference in levels: > 1.7 V 98 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024