Industrial — CODE 61 XX — RETARDER OIL TEMPERATURE HOT

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 61 XX — RETARDER OIL TEMPERATURE HOT Main code 61 indicates the ECU has detected a hot fluid condition in the output retarder. Table 6–7 shows what actions are taken by the ECU at elevated retarder temperatures. A. Active Indicator Clearing Procedure: Power down Manual Self-clearing B. Troubleshooting Possible causes (but not all causes) for hot fluid are: 1. Prolonged retarder use. 2. TID 2 transmission with ECU prior to Version 8A. 3. Low fluid level. 4. High fluid level. 5. A retarder apply system that allows the throttle and retarder to be applied simultaneously. 6. Cooler inadequately sized for retarder.

If the validity of the hot fluid diagnosis is in question, temperature can be checked by using a temperature gauge at the retarder-out port or by reading retarder temperature with the ATDT TM or Pro-Link ® diagnostic tool. Another method of checking retarder temperature is to remove the “T” connector at the ECU and measure resistance (Ohms) between terminals T28 and T25. Compare the resistance value to the value in Figure 6–21 to see if the result is within the expected operating range. For TID 2 thermistors, see Appendix Q for resistance versus temperature table. Table 6–7. Transmission Retarder Operation as a Function of Temperature NOTE:

Use the ATDT TM or Pro-Link ® diagnostic tool to determine the software version being used. 6–88 Copyright © 2001 General Motors Corp.

Description Version 8* MD and HD Retarder, Light On MD and HD Retarder, Light Off 166˚C (330˚F) 159˚C (318˚F) MD and HD Retarder, Set Hot Code (61 00) MD and HD Retarder, Clear Active Indicator 168˚C (335˚F) 162˚C (323˚F) MD and HD Retarder, Capacity Reduction 149–166˚C (300–330˚F) MD and HD Retarder, Reduced Capacity (retarder light begins flashing) MD and HD Retarder, Reduced Capacity (retarder light stops flashing) 146˚C (295˚F) 143˚C (289˚F) MD and HD Retarder, Auto Preselect On (after 12 seconds of retarder apply at retarder temperature shown — range to be preselected is a customer calibratable value). Auto Preselect remains on until retarder is deactivated.

143˚C (289˚F) MD and HD Retarder, Auto Preselect On (after 12 seconds of retarder apply and engine water temperature shown (actual value is a customer calibratable value which must be approved by the Allison calibration committee)). Auto Preselect remains on until retarder is deactivated. 82–124˚C (180–255˚F) MD and HD Retarder, Flashing Retarder Temperature Light Begins (shows that preselect downshifts are invoked) MD and HD Retarder, Flashing Retarder Temperature Light Stops (closed throttle downshifts not preselected) 140˚C (284˚F) 137˚C (279˚F) * Calibration values are subject to change.