Industrial — APPENDIX C — SOLENOID AND CLUTCH CHART

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX C — SOLENOID AND CLUTCH CHART LEGEND X Indicates solenoid is electrically ON. Y Indicates clutch is hydraulically applied. Blank Indicates solenoid is electrically OFF or clutch is not hydraulically applied. 0 Optional ON or OFF. * See NVL explanation below. NVL As a diagnostic response: If Turbine Speed is below 150 rpm when Output Speed is below 100 rpm and Engine Speed is above 400 rpm, Neutral Very Low ( NVL ) is commanded when N1 (Neutral) is the selected range. NVL is achieved by turning D solenoid “on” in addition to E solenoid being “on,” which locks the output. Otherwise, D solenoid is turned off in N1 (Neutral).

As a commanded range when shifting to Fire Truck Pump Mode: While wire 118 is energized before wire 117 is energized when going into Fire Truck Pump Mode, Neutral Very Low ( NVL ) will be commanded to lock the output to assist the shifting of the split-shaft PTO transfer case from road mode to pump mode. While wire 118 is de-energized before wire 117 is de-energized when shifting out of Fire Truck Pump Mode, Neutral Very Low ( NVL ) will be commanded to lock the output to assist the shifting of the split-shaft PTO transfer case from pump mode to road mode. Copyright © 2001 General Motors Corp.