WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX D — WIRE/CONNECTOR CHART A1 K3 V01240 VIM CONNECTOR (HARNESS 30-WAY) Figure D–23. VIM Connector (Harness) Terminal No. Color Wire No.
Description Termination Point(s)* A1 Blue 313NO Reverse Warning Relay — Normally Open A2 Yellow 314CM Output Wire 114 Relay — Common A3 Blue 314NO Output Wire 114 Relay — Normally Open B1 Yellow 313CM Reverse Warning Relay — Common B2 Green 314NC Output Wire 114 Relay — Normally Closed B3 Reserved C1 Orange 346 Ignition Power C2 Green 312NC Output Wire 112 Relay — Normally Closed C3 Reserved D1 Green 325NC Output Wire 125 Relay — Normally Closed D2 Green 332NC Output Wire 132 Relay — Normally Closed D3 Reserved E1 Yellow 325CM Output Wire 125 Relay — Common E2 Yellow 332CM Output Wire 132 Relay — Common E3 Blue 332NO Output Wire 132 Relay — Normally Open F1 Blue 323NO Neutral Start Relay — Normally Open F2 Yellow 312CM Output Wire 112 Relay — Common F3 Blue 312NO Output Wire 112 Relay — Normally Open G1 Yellow 323CM Neutral Start Relay — Common G2 Reserved G3 Reserved H1 Reserved H2 White 357UF Speedometer — Unfiltered H3 Reserved J1 Pink 336A Battery Power J2 Pink 336C Battery Power J3 Reserved K1 Gray 343A Battery Return K2 Gray 343C Battery Return K3 Reserved * Termination Points are determined by OEM electrical system design.
Copyright © 2001 General Motors Corp. D–31