WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX E — CONNECTOR PART NUMBERS, TERMINAL PART NUMBERS, TOOL PART NUMBERS, AND REPAIR INSTRUCTIONS 1–5. DELPHI-PACKARD METRI-PACK 280 SERIES CONNECTORS — PULL-TO-SEAT (INTERNAL HARNESS SOLENOID AND C3 PRESSURE SWITCH) A. Connector/Terminal Repairs Wire Stripper Crimping Tool J 35615 J 38125-7 NOTE: Crimping anvils will be listed following the terminal part numbers for the various connectors in this section. The anvil for the core crimp is always listed first.
Remover Tool J 38125-13 Use Description Manufacturers P/N Solenoid/C3 Pressure Switch (Switch) Connector 12092420 C3 Pressure Switch (Harness) Connector 12110139 Solenoid/C3 Pressure Switch (Switch) Terminal (Use crimping anvils “C” and “D”) 12124639 C3 Pressure Switch (Harness) Terminal (Use crimping anvils “C” and “D”) 12066337 Solenoid (A, B, and G) Terminal (2 Wire) B (Use crimping anvils “A” and “B”) 12015243 B. Terminal Removal 1. Depress locktab on terminal (accessible in slot of connector) and push terminal out front of connector (Figure E–5, View A). 2. If replacing terminal, cut terminal between core and insulation crimp (to minimize wire loss). C. Terminal Crimping 1.
Carefully strip insulation 6.5 mm ± 0.5 (0.26 ± 0.02 inch). Unless insulation crimp is overtight, Automatic Wire Stripper J 35615 will remove insulation and crimp from old terminal without damaging wire). 2. Place core crimp portion of terminal on bed of anvil indicated and squeeze crimper enough to hold terminal from dropping (Figure E–5, View B). 3. Position wire core in terminal and squeeze crimper tool to complete the core crimp. Be sure to orient the terminal so that it is properly aligned with the terminal cavity in the connector. (When crimping two wires in terminal P/N 12015243, strip and twist cores together before inserting into the terminal.) 4.
Position insulation crimp of terminal on anvil indicated so that the entire insulation crimp area and a portion of the terminal between the core and insulation crimp areas are supported by the anvil. Complete the insulation crimp. 5. Slip the wire through the slot in the connector and pull to fully seat the terminal(s). Copyright © 2001 General Motors Corp. E–19