WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX E — CONNECTOR PART NUMBERS, TERMINAL PART NUMBERS, TOOL PART NUMBERS, AND REPAIR INSTRUCTIONS 1–8. AMP PRODUCTS CONNECTORS (8-WAY RMR DEVICE (HAND LEVER)) A. Connector/Terminal Repairs Crimping Tool J 38125-7 Wire Crimp Anvil “E” Remover Tool J 38125-13 Insulation Crimp Anvil “A” Use Description Manufacturers P/N 8-Way RMR Device (Hand Lever) 8-Way Receptacle Terminal (Socket) 163007-0 42100-2 B. Terminal Removal 1. Insert removal tool J 38125-13 into the small notch at the front of the connector to release the ter- minal locktab (Figure E–9, View A). 2. Pull the terminal and wire out the back of the connector. 3.
If replacing terminal, cut terminal between core and insulation crimp (this minimizes wire loss). C. Terminal Crimping 1. Strip wire to approximately 4.0 ± 0.25 mm (0.16 ± 0.01 inch) (Figure E–9, View B). 2. Place new terminal onto crimping tool J 38125-7, anvil “E” (Figure E–9, View C). 3. Slightly close the crimping tool to hold the terminal steady. 4. Insert the wire so that the stripped portion of the wire is in the core crimp area and the insulated portion of the wire is in the insulation crimping area. 5. Crimp the stripped section of the wire (Figure E–9, View B). 6. Remove the terminal from the crimping tool. 7.
Use a pair of needle nose pliers, if necessary, to start the bend on the insulation crimp wings. 8. Crimp the insulated section of the wire using anvil “A” of the crimpers (Figure E–9, View C). 9. Remove the terminal from the crimping tool. 10. Tug on the terminal to make sure the crimp is tight. 11. Insert the terminal into the connector. The terminal will “click” into place and should not pull out. Copyright © 2001 General Motors Corp. E–29