Freightliner — 122SD, Coronado 132

Exhaust 49 3. If present, check the condition of the insulation material around the exhaust pipe between the turbocharger and the ATD. See the engine manufacturer’s maintenance manual for filter replacement instructions and maintenance intervals. 4. Check the ATD mounting bands for tightness. Tighten to 30 lbf·ft (41 N·m) if needed. Do not overtighten. ADR2011 Exhaust System Inspection 5. Check for leaks around the clamps that attach the ATD in the ATS, and around the clamps that retain the DPF in the ATD. IMPORTANT: The Australian Department of In- frastructure and Transportation regulations for 2011 (ADR2011) require lower exhaust emis- sions, thus requiring new exhaust system com- ponents.

See Fig. 4 . In particular the aftertreat- ment device (ATD), which is part of the aftertreatment system (ATS), requires special attention during regularly scheduled mainte- nance inspections. If any discrepancies are dis- covered, refer to the engine manufacturer’s ser- vice literature for repair instructions. 6. Check all sensors attached to the ATS for leaks or damaged wires. No leaks are allowed. See Fig. 1 , Fig. 2 , or Fig. 3 for Detroit Diesel ATS sensor locations. 7. Check the DPF exterior surface for dents or other damage. A dent over 3 inches (76 mm) in diameter and 1/4-inch (6-mm) deep could cause internal damage to the DPF, causing it to mal- function. 8.

Check the SCR catalyst for dents and other damage. Inspection 1. Check for leakage at the clamp that attaches the exhaust pipe to the turbocharger exhaust outlet. If leakage exists, tighten the nut on the clamp to the required torque. If leakage persists, install a new clamp. 9. Check for heat discoloration on the surface of the ATD. Heat discoloration may indicate internal damage; especially around the DPF. NOTE: Diesel exhaust fluid creeps, causing white crystals to form around the line fittings. The presence of crystals does not mean the system has a leak. Replacing fittings or trouble- shooting components is not necessary unless there is a system failure or a fault code. 2.

Check the exhaust pipe, bellows, and each ex- haust seal clamp for leakage, wear, cracks, or damage. Replace damaged components as needed. If leakage exists at a clamp, tighten the nuts to the required torque. If leakage persists, install a new exhaust seal clamp. Do not reuse seal clamps. Once a seal clamp is loosened or removed, it must be replaced. 10. Check the DEF tank, pump, metering unit, and lines for leaks. See Section 49.01 of the 122SD and Coronado Workshop Manual for repair pro- cedures. 3. If present, check the condition of the insulation material around the exhaust pipe between the turbocharger and the ATD. 11.

Check any wires, lines, or hoses within 4 inches (10 cm) of the exhaust system for heat damage. Repair or reroute as needed. Diesel Exhaust Fluid (DEF) Filter Replacement 4. Check the ATD mounting bands for tightness. Tighten to 30 lbf·ft (41 N·m) if needed. Do not overtighten. 5. Check for leaks around the clamps that attach the ATD in the ATS, and around the clamps that retain the DPF in the ATD. No leaks are allowed anywhere in the system. The Environmental Protection Agency’s 2010 regula- tions require lower nitrogen oxide (NOx) exhaust emissions. Selective catalytic reduction (SCR) uses diesel exhaust fluid (DEF) to lower NOx emissions in the vehicle exhaust.

A filter in the DEF pump pre- vents clogging of the DEF metering unit injection nozzle. 6. Check all sensors attached to the ATD for leaks or damaged wires. No leaks are allowed. 7. Check the DPF exterior surface for dents or other damage. See Item A of Fig. 4 . A dent over 3 inches (76 mm) in diameter and 1/4-inch (6- 122SD and Coronado 132 Maintenance Manual, February 2016 49/2