Freightliner — 122SD, Coronado 132

Rear Axle 35 Dana Spicer Drive Axle Lubricant Capacities Axle Type Axle Model Capacity * : Pints (liters) Double Reduction DP463P 40 (18.9) 1 * Quantities listed are approximate. Fill axle until lubricant is level with bot- tom of fill hole with vehicle on level ground. Add 2 pints (1 L) of additional lubricant to the power divider. Table 6, Dana Spicer Drive Axle Lubricant Capacities NOTE: Some Dana Spicer axles have a small tapped and plugged hole near and below the housing oil fill hole. This smaller hole is for a lubricant temperature indicator only, and should not be used as a fill or level hole. 2 3 f350021a 08/06/93 1. Housing Cover Gasket 2. Oil Fill Plug 3.

Shift Unit Housing Cover 6.1 With the vehicle on a level surface, fill the axle through the oil fill hole or standpipe opening. Lubricant should be level with the bottom of the oil fill hole, or the top of the standpipe opening. To check fluid level, see Fig. 2 . Fig. 6, Two-Speed-Axle Shift Unit (sulfated ash content must not exceed 1.85%). This cold-weather mixture can be safely used up to 32°F (0°C). 6.2 Install and tighten the fill plug 40 to 60 lbf·ft (54 to 81 N·m). Two-Speed Axles With Shift Unit Commercially available automatic transmission fluid may be used in place of SAE 10 engine oil. Automatic transmission fluid can be used for all temperatures; do not mix it with kerosene.

To prevent component damage, do not mix engine oil and automatic transmission fluid. IMPORTANT: Also do the appropriate procedure under the heading "All Axle Models." Dana Spicer and Meritor 4. Using the recommended lubricant, fill the shift unit housing through the oil fill hole until the lubri- cant is level with the bottom of the opening. 1. Remove the shift unit housing cover; see Fig. 6 . Drain and discard the old lubricant. Discard the housing cover gasket. 5. Coat the threads of the fill plug with a small amount of Loctite® 242, or equivalent sealant. Install the fill plug finger-tight in the rear axle shift unit housing. Using a wrench, tighten it an addi- tional 1-1/2 turns. 2.

Thoroughly wash the axle shift parts and housing cover, and allow them to air dry. 3. Install the housing cover and a new cover gas- ket. Tighten the housing cover capscrews 90 to 110 lbf·in (1020 to 1240 N·cm), then remove the oil fill plug from the cover. 35–02 Axle Breather and Axle Lubricant Level Inspection IMPORTANT: When the ambient temperature is above 0°F (–18°C), use SAE 10 heavy-duty en- gine oil, API service classification SD (sulfated ash content must not exceed 1.85%).

When the ambient temperature is below 0°F (–18°C), use one part kerosene to three parts SAE 10 heavy- duty engine oil, API service classification SD For all axles, including tandem drive axles and two- speed axles, perform the applicable procedures under the heading, "All Axle Models." For a two- speed axle with a shift unit, also check the shift unit 122SD and Coronado 132 Maintenance Manual, February 2016 35/6