Komatsu — CHECK BEFORE STARTING ENGINE, ADJUST

OPERATION OPERATION CHECKING WITH MACHINE MONITOR 1. Turn starting switch(1) to the ON position. 2. Check that all monitor lamps light up for 3 seconds, the warning lamp lights up for 2 seconds, and the alarm buzzer sounds for 1 second. REMARK G If the lamps do not light up, there may be a failure or dis- connection in the monitor, so please contact your Komatsu distributor. G When carrying out the checks before starting, do not relay only on the monitor. Always carry out all the items listed for "CHECK BEFORE STARTING (PAGE 3-40)". 3-41