MAN — Thermostat

169 Service data Dimensions Limit values Cover for heat exchanger Working valve opens at 0.85−1.15 bar overpressure 0.02−0.08 bar negative pressure Valve cap: Safety valve opens at 1.3−1.7 bar overpressure (pressure: 1.5 LR1103) Warning: When opening the cap with the working valve there is a risk that it may remain non−tight after it has been closed again. The overpressure required in the cooling system no longer builds up. Premature boiling occurs and coolant is lost. To prevent damage to the engine, this cap should only be opened in exceptional cir- cumstances and then replaced with a new one. Thermostat Opening begins at: 83_C (2_) Fully open:

95_C (The temperature for the start of opening is printed on the thermostat) 24.5−25.8 mm Lift at least 8 mm at 95_C