BF40AeBFSOA b. IGNITION SYSTEM These outboard motors are equipped with an engine overrev limiter which is provided in the ignition control module. The overrev limiter is activated when the engine speed exceeds 6,300 rpm. When activated the sparks are emitted to the No. 1, No. 2 and No. 3 cylinders. The overrev limiter may be activated under such conditions as; light pro- peller load or propeller ventilation. Hard Starting 1. Measure the spark plug gap and perform the spark test (See base shop manual). Standard plug: DR7EA (NGK), X22ESR-U (DENSO) Plug gap: 0.6 - 0.7 mm (0.24 - 0.28 in) I No spark or weak spark Goodspark 1 2. Perform the spark test again using a new spark plugs. No spark 3.
Check that the switch clip is installed on the emergency stop switch correctly. ___ Disengaged -4 Install the clip securely. I Installed c 4. Disconnect the blackhed wire of the Good spark emergency stop switch and perform spark test. No spark c 5. Disconnect the power coil wire con- nector, and check for resistance. Resistance: 7.02 - 8.58 Q Abnormal Normal c Go to page 2-8. 2-7