honda — Electrical Equipment

BF40AoBF50A 2. POWER COIL Disconnect the 2P power coil connector, and measure the resistance between the terminals. I Standard resistance I 7.02 - 8.58 R : P I POWER COIL WIRE See page 6-1 for the power coil replacement. 3. ECT (Engine Coolant Temperature) SENSOR The sensor resistance decreases as the coolant tem- perature increases as shown on the right table. 1) Disconnect the 2P connector from the thermo sensor and measure the resistance between the sensor ter- minals at the room temperature. Standard resistance: 1 - 5 k!2 2) Connect the 2P connector and start the engine and warm up the engine to normal operating temperature.

3) Stop the engine, and disconnect the 2P connector and measure the resistance. Standard resistance: 200 - 400 R 111 \ ECT SENSOR ECT sensor installation/removal is almost the same as installation/removal of the sermo switch. (See page 8-2 of the Base Manual.) kR 100 W 0 z 3 1 ; W U - E 0.1 10 0.01 - -50 0 50 1 1 I I I I -60 0 100 200 300°F [2] TEMPERATURE 1613