2. SERVICE INFORMATION BF40AoBF50A 1. MAINTENANCE STANDARDS 2. TORQUE VALUES 4. TROUBLESHOOTING 3. SPECIAL TOOLS I 1. MAINTENANCE STANDARDS POWER TRlM/TlLT Part I Item I Standard I Service limit Power trimhilt Lower chamber blow pressure 19.3 - 23.0 MPa (1 97 - 235 kgf/cmz, 2,802 - 3,342 psi) Upper chamber blow pressure 27.9 - 34.8 MPa (285 - 355 kgWcm’, - 4,054 - 5,049 psi) Power t rim/t ilt motor Brush length Mica depth 9.75 mm (0.384 in) 1.8 mm (0.07 in) 5.5 mm (0.22 in) 1.3 mm (0.05 in) 2. TORQUE VALUES Torque Item Thread dia.
x pitch Note Power trimhilt Upper joint metal Oil hole cap bolt Oil tank socket bolt Outer tube Outer tube guide Gear pump socket bolt Spool valve cap Manual valve 2- Way valve Motor screw Yoke screw N-m kgfom Ibf-ft M14 x 1.5 44 1.1 4.7 64 88 5.1 22 1.7 7 6.4 2.2 4.5 0.1 1 0.48 6.5 9.0 0.52 2.2 0.17 0.7 0.65 0.22 33 0.80 3.5 47 65 3.8 16 1.2 6.1 4.7 1.6 3/8- 1 6U N C M5 x 0.8 M41 x 1.5 M52 x 1.5 M5 x 0.8 M22 x 1 .O M12 x 1.75 M12 x 1.0 M5 x 0.8 1/4-20 UNC NOTE: (1): Apply LOCTITEO #271 to the thread (See page 13-28). (2): Apply LOCTITEO #241 to the thread (See page 13-21). 2-1