BF40AoBFSOA 3) Push the "DN" side of the power trimhilt switch and compress the piston rod fully. With the piston rod compressed fully, measure the upper chamber blow pressure by reading the pressure gauge. [l] Compress fully. BLOW PRESSURE (Upper chamber side) 27.9 - 34.8 MPa (285 - 355 kgf/crn2, 4,504 - 5,049 psi) If the blow pressure is out of the specified range, check each part of the power trimhilt assembly for oil leakage. If there is no oil leakage but the blow pressure drops below the specified pressure quickly, the power trimkilt motor assembly can be faulty. Replace the motor assembly with a new one and measure the blow pressure again.
4) Push the "UP" side of the power trimhilt switch and extend the piston rod fully. [l] SEALING WASHER \ (S.] [2] GAUGE JOINT A 07OPJ-V150100 u \ 5) Remove the special tool and pressure gauge from the valve body. Install the sealing washer, manual valve and the internal circlip in the valve body. Be sure to remove the special tool with the piston rod fully extended, or ATF spurts out. A small amount of ATF flows out after removing the tool. Install the manual valve quickly. Install the sealing washer securely not to let it col- lapse in the valve body. 6) Tighten the manual valve to the specified torque. TORQUE:
1.7 N*m (0.17 kgf*m, 1.2 Ibfeft) / [6] MANUAL VALVE 7) With the piston rod fully extended, check whether ATF level is at the edge of the filler port of the oil tank (P. 13-28). If the oil level is low, add ATF up to the edge of the filler port. [5] INTERNAL ClRCLlP / [4] PRESSURE GAUGE (Commercially available) 13-31