. MAINTENANCE SERVICE PROCEDURE CHECK AND ADJUST AIR CONDITIONER pulley and compressor pulley with a finger force of approx. 6 kg (58.8 N). When the V-belt is new, it will stretch at first, so always adjust it after 2 or 3 days. CHECK LEVEL OF REFRIGERANT(GAS) WARNING 4 - 41 CHECK TENSION OF COM PRESSOR BELT If t he belt is loose, it wil l slip and will not be able to carr y out cooling properly. Check the belt tension from time to time. The deflectio n should be 10 mm (0.4 in) when pr essed at a point midway betwe en the drive When handling refri regulations.
gerant gas, always follow local laws and The refrigerant used in the cooler is colorless and odorl ess and does not harm the atmosphe hands, it may cause lo re, but if the liquid gets into your e ss of sight or frostbite, so never lo yes or on your osen any part of the refrigerant circu it. If t he level of the refrig erant (gas) is low, the cooling effect will be reduced.
Run the engi ne at high idling, and check th refrigerant in the refrig erant circuit through the sight receiver (1) when the c No bubbles in refrig Some bubbles in flo (bubbles pass conti Colorless, transpare REMARK When there are bu bbles, the refrigerant gas level is low, so contact your refrige rant dealer to have refrigerant added. If the air conditioner is ru n with the refrigerant gas level low, it will e compressor. as the refrigerant. cause damage to th New R134a is used