Water Transfer Tubes - Cleaning and Inspection (08-09) Cooling System N14 Page 8-24 Warning: Do not straighten a bent fan blade or continue to use a damaged fan. Replace the original equipment fan with a fan of the identical part number. Cummins Engine Company, Inc. must approve any other fan changes. Water Transfer Tubes - Cleaning and Inspection (08-09) Cleaning Use a gasket scraper to remove gasket material from the mating surfaces of the transfer tubes. Use Scotch-Brite W 7448, Part No. 3823258, to clean the o-ring grooves on the thermostat housing to water pump water transfer tube. Warning: When using a steam cleaner, wear protective clothing and safety glasses or a face shield.
Hot steam can cause serious personal injury. Use solvent or steam to clean the parts. Dry with com- pressed air. Inspection Inspect the transfer tubes for cracks, dents, and corro- sion or pitting in the o-ring grooves.