Cummins — CLEANING

Electrical Equipment Alternator Bracket - Cleaning and Inspection for Reuse (13-01) N14 Page 13-3 Wiring Diagrams A complete collection of electrical wiring diagrams, as applied to all Cummins engines, is contained in Wiring Diagrams, Bulletin No. 3379099. Alternator Bracket - Cleaning and Inspection for Reuse (13-01) Cleaning Use solvent to clean the bracket. Dry with compressed air. Inspection Visually inspect the bracket for cracks and other damage. Discard damaged parts. NOTE: The cylinder block mounting surface must be clean and free of paint to provide a proper electrical ground for the alternator.

Alternator Adjusting Link - Cleaning and Inspection for Reuse (13-02) Cleaning Use solvent to clean the adjusting link. Dry with com- pressed air. Inspection NOTE: Some parts can vary in design. Visually inspect the adjusting link for cracks or damage. Discard damaged parts. Starting Motor - Cleaning and Inspec- tion for Reuse (13-03) Cleaning Warning: When using a steam cleaner, wear protective clothing and safety glasses or a face shield. Hot steam can cause serious personal injury. Use steam to clean the starting motor. Dry with com- pressed air.