hitachi — DTC: P0182 (Flash code 211) Fuel temperature sensor fault (low voltage fault, GND short)

1E-250 Electronic control fuel injection system (Common rail type) About FT sensor Characteristics of FT sensor The output voltage of FT sensor changes according to the fuel temperature. The scan tool with CAN communication displays a fixed value when the value exceeds the threshold voltage. Therefore, judge as it is more than the threshold value if the value of 30 ° C ( 22 ° F) or 120 ° C (248 ° F) is not changed. When error occurs, error value (214 ° C {419 ° F}) is displayed. The following illustration shows the correlation between physical value and voltage displayed in the scan tools with CAN communication.

Tech2 and scan tools with KW communication can display both physical value and voltage. (V) 4.5195 Name 1. GND 2. Signal 0.1973 -30 (-22) 120 (248) F TSWG0203 25 20 15 10 5 -30 (-22) 0 (32) 30 (86) 60 (140) 90 (194) 120 (248) TSWG0210 F