hitachi — DTC: P0183 (Flash code 211) Fuel temperature sensor fault (high voltage fault, open circuit or short to power supply circuit)

Electronic control fuel injection system (Common rail type) 1E-257 About FT sensor Characteristics of FT sensor The output voltage of FT sensor changes according to the fuel temperature. The scan tool with CAN communication displays a fixed value when the value exceeds the threshold voltage. Therefore, judge as it is more than the threshold value if the value of 30 ° C ( 22 ° F) or 120 ° C (248 ° F) is not changed. The following illustration shows the correlation between physical value and voltage displayed in the scan tools with CAN communication. Tech2 and scan tools with KW communication can display both physical value and voltage. (V) 4.5195 Name 1. GND 2.

Signal 0.1973 -30 (-22) 120 (248) F TSWG0203 Step Action Value YES NO 19 1. Check for followings in the ground circuit between ECM and FT sensor using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. • Open circuit • High resistance 2. If the trouble is detected, repair or replace as required. Is the trouble detected? — Go to Step 13. Go to Step 9.