Electronic control fuel injection system (Common rail type) 1E-351 Step Action Value YES NO 10 1. Check for followings in the circuit between QOS indicator lamp and ECM using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. • Open circuit • High resistance 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 14. Go to Step 12. 11 Replace the meter. Is the procedure completed? — Go to Step 14. — 12 Replace the QOS indicator lamp bulb. Is the procedure completed? — Go to Step 14. — 13 Is EMPS available? — Go to Step 14. Go to Step 15. 14 1.
Check the version of ECM software. 2. Rewrite the software if version upgraded is necessary. Refer to “How to use flash tool” in this section for check and rewriting of ECM. Note: EGR valve position learning is required after replacing or rewriting the ECM. Refer to “Engine Control System, Engine control module (ECM), Installation of ECM” in this section for learning of EGR. Is the procedure completed? — Go to Step 16. Go to Step 15. 15 Replace the ECM. Note: EGR valve position learning is required after replacing or rewriting the ECM. Refer to “Engine Control System, Engine control module (ECM), Installation of ECM” in this section for learning of EGR. Is the procedure completed?
— Go to Step 16. —