Electronic control fuel injection system (Common rail type) 1E-399 Step Action Value YES NO 6 1. Check the circuit between diagnosis lamp and ECM for ground short circuit using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 16. Go to Step 11. 7 1. Turn the key switch to “OFF”. 2. Remove the connector from the ECM. 3. Short between the diagnosis lamp control terminal of the ECM and the ground using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note:
If breaker box is not available, refer to “On- board check procedure for sensors”. 4. Turn the key switch to “ON”. 5. Check if the diagnosis lamp is ON. Does the diagnosis lamp come on? — Go to Step 13. Go to Step 8. 8 Check for installation condition of the meter, ECM connector and coupling connector. 1. Check for play or looseness in the connection. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 16. Go to Step 9. 9 1. Check for following in the circuit between the fuse and the diagnosis lamp. • Open circuit • Short circuit to ground circuit • High resistance 2. If the trouble is detected, repair as required. Is the trouble detected?
— Go to Step 16. Go to Step 10.