1E-404 Electronic control fuel injection system (Common rail type) Fuel system filter :Actual rail presure :Desired rail puressure 3 4 2 Absolute pressure t 1 > 8sec 5 Intensified limit Actual 1 P1094 5MPa(725.2psi) Actual 2 P1093 1 t 2 > 8sec TSWG0184 TSWG0159 Action taken when DTC is set Name 1. Fuel pump strainer 2. Pre-fuel filter 3. Main fuel filter 4. Electromagnetic pump filter 5. Gauze filter Trouble is displayed on the monitor of the machine or diagnosis lamp comes on. Back-up mode Filter clogging in the fuel system may establish the DTC set condition. Check as required.
Limited injection amount 3 (multi-injection stopped) target RP upper limit (80 MPa {11603 psi}) Preconditions when DTC is set Recovery from failure Key switch input voltage is 16V or more. DTC P0192, P0193, P1093, P0091, P0092, P1291, P1292, or P1635 is not detected. Coolant temperature is 60 ° C (140 ° F) or more, and 375 rpm or more. Refer to “List of diagnostic trouble code” and “About recovery from failure” in this section for recovery from failure. The conditions to clear the MIL/DTC The present trouble turns to history trouble when the condition is out of the range from DTC set condition (recovery from failure).
The diagnosis lamp will go off after the code turns to history trouble and the key switch is turned “OFF” then “ON” again. Using the scan tool, or memory clear switch and diagnostic switch operation enables to clear DTCs. DTC set condition When “No pump pressure feed (1st stage)” is completed, actual rail pressure lower than target rail pressure for 10 MPa (1450 psi) or more holds 8 seconds or more. Pressure feed indication is limit +1 ° CA or less, and actual rail pressure lower than target rail pressure for 10 MPa (1450 psi) or more holds 8 seconds or more. Diagnostic aid Followings are suspected as the cause.
Injector internal trouble Supply pump internal trouble Fuel system pipe fault (fuel leakage, clogging, crush, etc.) Fuel filter fault (clogging) Fuel tank fault (clogging) Pressure limiter trouble (operation under specified pressure, degradation of sealability) ECM trouble Common rail pressure sensor trouble