Electronic control fuel injection system (Common rail type) 1E-41 Move : Allows to view changes of data following the display screen. Trigger Frame: Displays a trigger point. More: Switches the displayed softkeys. 2. Pressing the softkey “Select Frame” causes the following screen. Choose the “More” on the plot display screen. Zoom In: Shows the abscissa by enlarging it (each press doubles the display). Zoom Out: Shows the abscissa by reducing it (each press halves the display). Over View: Shows the entire frame. More: Switches the displayed softkeys. Choose the “More” on the plot display screen. Time / Frame conversion: Switches the value in abscissa. More: Switches the displayed softkeys.
Select frame Select frame setup procedure 1. Press softkey “Select Frame.” TSWG0125 First Frame: First frame No. and data acquisition time from Trigger Point (calculated backward). Last Frame: Last frame No. and data acquisition time from Trigger Point (integrated). Go To Frame: Entering a frame No. allows to view its data. +/-: Only the “-” sign is displayed. 3. “1” entered via keys in the “Go To Frame” area. RPM MPa V V RPM V V % V V RPM RPM V V % MPa TSWG0103 TSWG0107 Frame No. 1 and recording time displayed, and data values in Display Area represent those of Frame 1.