hitachi — Installation

1C-8 Cooling system (6WG1 (Common rail)) Notes: Do not directly heat the thermostat. Either perform the measurements by covering the bottom of the thermostat container with a plate (2), or hanging and lowering it into water. When performing measurements, constantly stir the water (1) to prevent differences of temperature from happening. Inspection Thermostat Inspect the thermostat's pellet, spring, and caulking parts for damage. Legend 1. Stirring rod 2. Block As wax type thermostats have a large heat capacity, the action of the valve has a certain amount of time lag compared to the fluctuation in water temperature. Installation 1. Install the seal ring.

Face the lip section of the seal ring as shown in the diagram, and use a installer to install it. Installer; Thermostat seal ring: 1-8522-1034-0 Thermostat operational checks Put the thermostat into water and gradually increase the water temperature. Measure the temperature at which it starts to open, temperature at which it is fully open, and amount of lift. 2. Install the thermostat. Take care not to damage or scratch the seal ring and install the thermostat as shown in the diagram. Open start temperature 82°C Temperature when fully open 95°C Amount of lift 95°C / 11 mm