1E-8 Electric system (6WG1 (Common rail)) After starting the engine, the starter doesn't stop when the starter switch is turned off Main data and specifications Condition Probable cause Correction After starting the engine, the starter doesn't stop when the starter switch is turned off Bad return of the starter switch contact Replace the starter switch Bad return of the starter relay contact Replace the starter relay Short in the magnetic switch coil Replace the magnetic switch Model (maker) Mitsubishi Rating Voltage (V) Power output (kW) Time (Seconds) 24 7.0 30 Number of pinion teeth 11 Rotation direction (viewed from the pinion side) Right Mass (approximate) (kg) 12.7 No load characteristic Voltage/current (V/A) Number of revolutions (rpm) Less than 23.5/125 Over 3000 Load characteristic Voltage/current (V/A) Torque N⋅m {kg⋅m} Number of revolutions (rpm) Less than 15.8/500 Over 51.5 {5.25} Over 900 Locking characteristics Voltage/current (V/A) Torque N⋅m {kg⋅m} Less than 5/1600 Over 117.0 {11.9}